An MCP server for ABB controllers and RobotStudio
A server that lets an AI coding agent read, edit, build and run RAPID programs on ABB robot controllers and drive RobotStudio simulations, with explicit guards before anything touches a real robot.
Project facts
- Controllers
- ABB IRC5 and OmniCore, real and virtual
- Tools exposed
- 139 in version 1.2.0
- Channels
- PC SDK, Robot Web Services, and an add-in running inside RobotStudio 2026
- Safety
- Anything that changes state on a real controller needs an explicit flag on that call
- Built with
- C#, .NET, ABB PC SDK, Robot Web Services, RobotStudio SDK, Model Context Protocol
- When
- Jun to Jul 2026
- Status
- Completed
- Page updated
On this page
What it is
The Model Context Protocol lets an AI coding agent call tools. This server gives such an agent the tools a robot programmer uses with ABB equipment: find a controller, log on, read the RAPID program that is loaded, edit a module, build it and read the errors, run and stop execution, read and write signals, and take a backup. A second set of tools drives RobotStudio: stations, simulation control, collision checks, targets and paths, and screenshots.
Three ways in
No single ABB interface covers all of that, so the server combines three.
| Channel | Used for |
|---|---|
| PC SDK | Discovery and logon, controller state, RAPID execution and data, I/O, the event log, files, backup and restore |
| Robot Web Services | Reading and writing live module text, build feedback, and raw access to the REST interface |
| An add-in inside RobotStudio, reached over a local named pipe | Stations, virtual controllers, simulation, collision, targets and paths, geometry |
The three run on different .NET runtimes. The server and the PC SDK code target .NET Framework 4.8, while RobotStudio 2026 hosts add-ins on .NET 10. So the add-in runs inside RobotStudio as its own side of the bridge, and the two sides share one protocol contract.
Guards
- Virtual controllers allow everything. Real controllers refuse any state-changing call (starting
execution, writing signals or data, restart, restore, moving the program pointer) unless that call
carries an explicit
allow_realflag. - Mastership is taken for one operation and released afterwards, unless it is held on purpose.
- Several RobotStudio windows. Each hosts its own bridge. With more than one open, the server lists them and refuses to guess which one a call is meant for, so an edit cannot land in the wrong station.
- A long operation cannot hang the agent. Station operations are serialised per session, a second one gets a clear “busy” answer, and the status call stays responsive while RobotStudio’s main thread is blocked.
Engineering
- Built in three and a half weeks: 21 commits from 10 June to 4 July 2026.
- Unit tests, plus a verification script that exercises the tools against a live virtual controller.
- A review of version 1.1.0 found 15 defects, which were fixed before version 1.2.0.
Limits
These come from ABB’s interfaces and are documented with the tools:
- The PC SDK has no breakpoint interface. Stepping uses ABB’s execution modes instead.
- Module text goes through Robot Web Services, because the PC SDK cannot read it.
- Creating a new virtual controller system from a robot model is internal to RobotStudio. The server works from an existing system or a packed station.